6ES7123-1JA00-0AB0 ET200L-SC, EL-MOD., 1AI, PT100

Product Code: 6ES7123-1JA00-0AB0

Availability: In Stock

Price: $105.49
  
 

SIMATIC SC,ELECTRONIC SUBMODULE 1 AI RTD PT100,N:100,0..600 OHM
Supply voltage
Load voltage 1L+
Rated value (DC) 24 V
Reverse polarity protection Yes
Input current
from supply voltage L+, max. 30 mA
Power losses
Power loss, max. 0.6 W
Hardware configuration
Rack
Required terminal block TB 16SC
Slots
Required slots 1; from 8
Analog inputs
Number of analog inputs 1
permissible input voltage for voltage input (destruction limit), max. 10 V; 10 V continuous, 25 V for max. 1 s
Cycle time (all channels), typ. 110 / 130 ms
Input ranges
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), resistance thermometers
Ni 100 Yes; Standard; -60 to +250 °C
Input resistance (Ni 100) 1 MΩ
Pt 100 Yes; Climate: -120 to +130 °C; standard: -200 to +850 °C
Input resistance (Pt 100) 1 MΩ
Input ranges (rated values), resistors
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 1 MΩ
Thermocouple (TC)
Temperature compensation
Parameterizable No
Characteristic linearization
Parameterizable Yes; Pt100 to DIN IEC 751, Ni100 to DIN 43760
Cable length
Cable length, shielded, max. 50 m
Analog value creation
Measurement principle integrating
Integrations and conversion time/resolution per channel
Resolution with overrange (bit including sign), max. 14 bit; S7 representation: 0 to 600 ohms: 14 bits, Pt100 climate: 0,1 °C/digit, Pt100 standard: 0,1 °C/digit, Ni100 standard: 0.1 °C/digit; S5 representation: 0 to 600 ohms: 13 bits, Pt100 climate: 0.05 °C/digit, Pt100 standard: 0.5 °C/digit, Ni100 standard: 0.5°C/digit
Integration time, parameterizable Yes
Basic conversion time, ms 110 / 130 ms
Integration time, ms 50 / 60 ms
Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Smoothing of measured values
Parameterizable Yes; parameterizable in 4 stages by means of digital filtering
Step: None Yes; 1 x cycle time
Step: low Yes; 8 x cycle time
Step: Medium Yes; 64 x cycle time
Step: High Yes; 128 x cycle time
Encoder
Connection of signal encoders
for resistance measurement with four-wire connection Yes; with compensation of line resistors
Connectable encoders
Constant measurement current for resistance-type transmitter, typ. 1.5 mA
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.05 %
Temperature error (relative to input range), (+/-) 0.03 %/K
Crosstalk between the inputs, min. 50 dB; At 50/60 Hz
Repeat accuracy in steady state at 25 °C (relative to input area), (+/-) 0.1 %
Operational limit in overall temperature range
Resistance thermometer, relative to input area, (+/-) 1 %; 0 to 600 ohms +/-1.0%; Pt100 (climate), 4 °C; Pt100 (standard) 8°C; Ni100 (standard) 4 °C
Basic error limit (operational limit at 25 °C)
Resistance thermometer, relative to input area, (+/-) 0.7 %; 0 to 600 Ohm +/-0.7 %; Pt100 (climate) 1 °C; Pt100 (standard) 4°C; Ni100 (standard) 2 °C
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min. 70 dB
common mode voltage (USS < 2.5 V) , min. 90 dB
Interfaces
PROFIBUS DP
Transmission rate, max. 9,6 kbit/s
Interrupts/diagnostics/status information
Alarms
Alarms No
Diagnostic messages
Diagnostic functions No
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus No; Optocoupler
between the channels and the power supply of the electronics No
Permissible potential difference
between inputs and MANA (UCM) 2 V DC / 2 Vpp AC
Isolation
Isolation checked with 1500 V AC
Dimensions
Width 10 mm
Height 64 mm
Depth 51 mm
Weights
Weight, approx. 20 g