6GK5786-1AB60-2AB0 SCALANCE W786-1PRO (USA)

Product Code: 6GK5786-1AB60-2AB0

Availability: In Stock

Price: $657.60
Artikelnummer 6GK5786-1AB60-2AB0
Product type designation SCALANCE W786-1PRO
Product description
IWLAN ACCESS POINT SCALANCE W786-1PRO, ONLY FOR USE IN USA, IEEE 802.11B/G/A/H, INDUSTRIAL WIRELESS LAN (IWLAN) 2.4/5 GHZ, UP TO 54MBIT/S, WPA2/802.11I/11E, NOTE NATIONAL APPROVALS, 48VDC, IP65(-40-+70 DGR C), 2X EXT. ANTENNA CONNECTIONS, 1 RADIO INTERFACE, FO (GLASS-FO, MULTIMODE)SOCKET, SCOPE OF SUPPLY: MOUNT. MAT., MANUAL ON CD ROM, GERMAN/ ENGLISH; 48VDC TERMINAL BLOCK
Transmission rate
Transfer rate
● with WLAN / maximum 54 Mbit/s
● for Industrial Ethernet 10 Mbit/s, 100 Mbit/s
● Note Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)
Interfaces
Number of electrical connections
● for power supply 1
● for redundant voltage supply 1
Design of the electrical connection
● for power supply 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)
Number of optical interfaces
● for fiber optic cable / at 100 Mbit/s 1
Design of the optical interface
● for fiber optic cable / at 100 Mbit/s Duplex multimode FOC (ST)
design of the removable storage
● C-PLUG Yes
● KEY-PLUG No
Interfaces / wireless
Number of radio cards / permanently installed 1
Number of electrical connections / for external antenna(s) 2
Design of the electrical connection / for external antenna(s) R-SMA (socket)
Product property / external antenna can be mounted directly on device No
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage / 1
● from terminal block 48 V
Supply voltage
● from Power-over-Ethernet acc. to IEEE802.3at for type 1 and IEEE802.3af 48 V
● from optional integrable power supply
— with AC 100 ... 240 V
— for DC 12 ... 24 V
Consumed current
● for DC / at 24 V / typical 0.34 A
● for DC / at 48 V / typical 0.17 A
● with AC / at 230 V / typical 0.04 A
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 0.34 A
Active power loss
● for DC / at 24 V / typical 8 W
● for DC / at 48 V / typical 8 W
● with AC / at 230 V / typical 8 W
● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 8 W
Permitted ambient conditions
Ambient temperature
● during operation -40 ... +70 °C
● during storage -40 ... +85 °C
● during transport -40 ... +85 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum 100 %
Ambient condition / for operation When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible
Protection class IP IP65
Design, dimensions and weight
Width / of the enclosure / without antenna 251 mm
Height / of the enclosure / without antenna 251 mm
Depth / of the enclosure / without antenna 72 mm
Net weight 2.24 kg
Mounting type For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required
● S7-1500 rail mounting No
● wall mounting Yes
Wireless frequencies
Radio frequency
● for WLAN in 2.4 GHz frequency band 2.41 ... 2.48 GHz
● for WLAN in 5 GHz frequency band 4.9 ... 5.8 GHz
Product properties, functions, components / general
Product function / Access Point Mode Yes
Product function / Client Mode Yes
Number of SSIDs 8
Product function
● Dual Client No
● iHOP No
● iPCF Access Point No
● iPCF client No
● iPCF-MC Access Point No
● iPCF-MC client No
Number of iPCF-capable radio modules 0
Product functions / management, configuration
Number of manageable IP addresses / in client 8
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● configuration with STEP 7 in the TIA Portal Yes
● operation with IWLAN controller No
● operation with Enterasys WLAN controller No
● iQoS Yes
● forced roaming with IWLAN Yes
● WDS Yes
Protocol / is supported
● Address Resolution Protocol (ARP) Yes
● ICMP Yes
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● DCP Yes
● LLDP Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Product functions / Diagnosis
Product function
● PROFINET IO diagnosis Yes
● Link Check Yes
● connection monitoring IP-Alive Yes
● localization via Aeroscout Yes
● SysLog Yes
Protocol / is supported
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Product functions / VLAN
Product function
● function VLAN with IWLAN Yes
Product functions / DHCP
Product function
● DHCP client Yes
● in Client Mode / DHCP server via LAN Yes
Product functions / Redundancy
Protocol / is supported
● STP/RSTP Yes
Product functions / Security
Product function
● ACL - MAC-based Yes
● Management security, ACL-IP based No
● IEEE 802.1x (radius) Yes
● NAT/NAPT Yes
● access protection according to IEEE802.11i Yes
● WPA/WPA2 Yes
● TKIP/AES Yes
Protocol / is supported
● SSH Yes
Product functions / Time
Protocol / is supported
● SNTP Yes
● SIMATIC Time No
Standards, specifications, approvals
Standard
● for hazardous zone EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
● for safety / from CSA and UL UL 60950-1 CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4
Certificate of suitability
● EC declaration of conformity Yes
● CE marking Yes
● C-Tick Yes
● E1 approval Yes
● Railway application in accordance with EN 50155 No
● NEMA4X Yes
● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af Yes
Standard for wireless communication
● IEEE 802.11a Yes
● IEEE 802.11b Yes
● IEEE 802.11e Yes
● IEEE 802.11g Yes
● IEEE 802.11h Yes
● IEEE 802.11i Yes
● IEEE 802.11n No
Wireless approval For operation in the USA, you can find more detailed information at: www.siemens.com/simatic-net/ik-info
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (NK) Yes
● Polski Rejestr Statkow (PRS) No
Accessories
accessories 48 V DC terminal block included in scope of delivery
Further Information / Internet Links
Internet-Link
● to website: Information and Download Center http://www.siemens.com/automation/net/catalog
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support http://support.automation.siemens.com
last modified: 23.10.2014
Date
31.10.2014
Changes preserved
© Copyright Siemens AG 2014

Write a review

Note: HTML is not translated!

Rating: Bad Good

Enter the code in the box below: